Drip Casing

Drip leg directs moisture away from openings and foundation walls

Designed to be used above window and door openings or at the foundation line to assist with moving moisture away from the wall. May be used in combination with casing bead or as a stand-alone for flashing

Application(s): EIFS, DEFS, Stone Veneer, Stucco

Designed to be used above window and door openings or at the foundation line to assist with moving moisture away from the wall. May be used in combination with casing bead or as a stand-alone for flashing. Caulk all intersections, butt joints, ends and corners at time of installation. Available in white, gray, tan and brown. If a custom color is required, please contact a ClarkDietrich sales representative or customer service. 

Product Data & Ordering Information

Product codeGround / Insul thickness (A)Back flange (B)Drip leg (C)Pcs./Box
DCB50-251/2"2"1/4"50
DCB58-255/8"2"1/4"50
DCB75-253/4"2"1/4"50
DCB78-257/8"2"1/4"50
DCB100-251"2"1/4"50
DCB150-251-1/2"2"1/4"50
DCB200-252"2"1/4"50
DCB300-253"2"1/4"30
DCB400-254"2"1/4"30
DCB50-381/2"2"3/8"30
DCB58-385/8"2"3/8"50
DCB75-383/4"2"3/8"50
DCB78-387/8"2"3/8"50
DCB100-381"2"3/8"50
DCB150-381-1/2"2"3/8"50
DCB200-382"2"3/8"50
DCB300-383"2"3/8"30
DCB400-384"2"3/8"30

Contact your ClarkDietrich Sales Representative for profile and market availability.
Notes: If weep holes are required, add W to the product code, example: DCBW75-25.
If a 3" or 3-1/2" back flange is required refer to Drip Flashing
If an arched profile is required refer to Archmaker Drip Flashing

Code Approvals & Performance Standards

  • ASTM C1063 Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
  • ASTM C1780 Standard Practice for Installation Methods for Cement-based Adhered Masonry Veneer
  • ASTM C1861 Standard Specification for Lathing and Furring Accessories, and Fasteners, for Interior and Exterior Portland Cement-Based Plaster
  • ASTM D1784 Standard Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
  • ASTM D4216 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) and Related PVC and Chlorinated Poly(Vinyl Chloride) (CPVC) Building Products Compounds
  • ASTM E2110 Standard Terminology for Exterior Insulation and Finish Systems (EIFS)
  • ASTM E2511 Standard Guide for Detailing of EIFS-Clad Barrier and Drainage Wall Assemblies
  • SDS Vinyl Corp PVC Compounds

STORAGE

All stored materials shall be kept dry.  Materials shall be stacked off the ground, supported on a level platform, and protected from the weather.

Product Submittal Sheets

Click the below Product Code to view Submittal/Tech Datasheet.

Product Code Description
DCB-25 Drip Flashings with 1/4" Drip Leg
DCB-38 Drip Flashings with 3/8" Drip Leg

ClarkDietrich SubmittalPro®

Submittal sheets for the exact product you're looking for can be created by using ClarkDietrich's SubmittalPro® Product Submittal System.