The clips are used to hold the area separation wall assembly in place at the floor, roof and truss line between adjacent units.
ClarkDietrich Aluminum Burn Clips are used as part of the ClarkDietrich H-Stud Area Separation Wall assembly and are designed to melt and break away when exposed to fire. The clips are used to hold the area separation wall assembly in place at the floor, roof and truss line between adjacent units.
Should a fire break out in one unit, the Aluminum Burn Clips on the fire-ridden side of the area-separation wall will melt, allowing the wall structure for that side to collapse. The Aluminum Burn Clips on the non-fire side will remain intact and hold the area separation wall in place as a barrier to contain the fire within the unit of origin.
Other custom Breakaway Clip lengths available
* For use with 3 Hour Design Assembly based on GA File No. ASW 2600 (USG)
Check listed Fire Rated Assembly Reports (in Technical Data Tab) for details of construction, thickness and length of required burn clips.
Member | Size | Thickness |
---|---|---|
AB - Breakaway Clip | 2" x 2" x 2-1/2" long | 0.050" Aluminum Clip |
AB63 - Breakaway Clip | 2" x 2" x 2-1/2" long | 0.063" Aluminum Clip |
AB40* - Breakaway Clip* | 2" x 2" x 4" long | 0.063" Aluminum Clip |
Check listed Fire Rated Assembly Reports below for details of construction, thickness and length of required burn clips.
Intertek Fire-Rated Design - 2 Hours, Non-Bearing Symmetrical Area Separation Wall - LISTING INFORMATION of ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies (9/7/16)
UL Design No. W454 (National Gypsum Co.)
(2) Layers of 1” thick gypsum board liner panels fit into H-Studs w/ (1) layer of 5/8” thick gypsum board on each side of wall assembly. Standard 2-1/2” long Aluminum Breakaway Clips can be used to secure assembly.
GA File No. ASW 2600 (USG)
(2) Layers of 1” thick gypsum board liner panels fit into H-Studs w/ 2” mineral fiber insulation on each side of wall assembly. Extra-long 4” Aluminum Breakaway Clips will need to be used secure assembly allowing for the 2” mineral insulation standoff.
Reference design assemblies and gypsum board manufacturer for details of the wall system.
Check listed Fire Rated Assembly Reports (in Technical Data Tab) for details of construction, thickness and length of required burn clips.
Click the below Product Code to view Submittal/Tech Datasheet.
Product Code | Description |
---|---|
AB, AB63, AB45, AB40, AB35, AB30 | Aluminum Burn Clip |
Submittal sheets for the exact product you're looking for can be created by using ClarkDietrich's SubmittalPro® Product Submittal System.