Perforated flange allow the base coat mixture to easily flow through and bond with the substrate.
Surface-mounted reveal used at the juncture of walls, ceilings, or other dissimilar materials. Always use a rigid backing or blocking material behind surface-mounted reveals.
Vent clips are provided with vented channel reveals to connect reveal sections and to assist in the alignment of the reveals.
Caulk all intersections, butt joints, ends, and corners at the time of installation.
Not to be used in lieu of control joints or expansion joints. Factory-fabricated intersections are also available for all ClarkDietrich channel reveals.
Product code | Finish thickness | Minimum board thickness | Reveal | Perforated flanges | Pcs./Box |
---|---|---|---|---|---|
AFDCV50-150SE | 1/16" - 3/32" | 1/2" | 1-1/2" | 1-1/8" | 25 |
AFDCV50-200SE | 1/16" - 3/32" | 1/2" | 2" | 1-1/8" | 25 |
AFDCV50-300SE | 1/16" - 3/32" | 1/2" | 3" | 1-1/8" | 20 |
AFDCV50-400SE | 1/16" - 3/32" | 1/2" | 4" | 1-1/8" | 20 |
AFDCV58-150SE | 1/16" - 3/32" | 5/8" | 1-1/2" | 1-1/8" | 20 |
AFDCV58-200SE | 1/16" - 3/32" | 5/8" | 2" | 1-1/8" | 20 |
AFDCV58-300SE | 1/16" - 3/32" | 5/8" | 3" | 1-1/8" | 20 |
AFDCV58-400SE | 1/16" - 3/32" | 5/8" | 4" | 1-1/8" | 20 |
Notes:
Vented Area: 1-1/2" reveal = 5 sq. in. per LF
2" reveal = 7 sq. in. per LF
3" reveal = 8 sq. in. per LF
4" reveal = 9 sq. in. per LF
Product Specifications
Installation Standards
Click the below Product Code to view Submittal/Tech Datasheet.
Product Code | Description |
---|---|
AFDCV50-150SE, AFDCV50-200SE, AFDCV50-300SE, AFDCV50-400SE AFDCV58-150SE, AFDCV58-200SE, AFDCV58-300SE, AFDCV58-400SE |
Architectural Vented "F" Channel Reveal - Surface Mount |
Submittal sheets for the exact product you're looking for can be created by using ClarkDietrich's SubmittalPro® Product Submittal System.