Code Approvals and MSDS

ClarkDietrich's Shaftwall code approvals and performance standards

ClarkDietrich Shaftwall Framing System meets or exceeds these applicable performance standards.

Link to ClarkDietrich's Material Certifications / Code Approvals

PEI Assembly Evaluation report AER-12061

Link to Fire Rated Test Reports

Link to Shaftwall Sound Rated Test Reprots

Link to ClarkDietrich's MSDS Reports

 

Code Compliance

(Also listed in the PEI AER-12061 report)

  • Meets or exceeds the requirements as stated in Section 703.2 of the 2012 International Building Code for Fire Resistance Ratings of building elements, components, or assemblies with the test procedures set forth in ASTM E119.
  • Meets or exceeds the requirements as stated in Section 703.2.1 of the 2012 International Building Code for Nonsymmetrical wall construction of Interior Walls and partitions shall be tested with both faces exposed to the furnace and the assigned fire-resistance ratings shall be the shortest durations obtained from two tests conducted in compliance with ASTM E119.
  • Meets the requirements for Fire Resistance ratings for shaft enclosure of not less than 2 hours as stated in Section 713.4 of the 2012 International Building Code.
  • Meets the requirements for construction for shaft enclosures as fire barriers in accordance with Section 707 of the 2012 International Building Code.
  • Meets or exceeds the requirements as stated in Section 2203.1 of the 2012 International Building Code for Identification and Protection of Steel for Structural Purposes
  • Meets or exceeds the requirements as stated in Section 2203.2 of the 2012 International Building Code in regards to painting of structural steel members as required in AISI S200 & S100.